Some of the functionalities will not work if javascript off. Please enable Javascript for it.
Official Website of Rajiv Gandhi Institute of Petroleum Technology, Jais, Amethi, India. / Facilities / Spectroscopic Analyses


Spectroscopic Analyses

Confocal Raman Spectrophotometer


Coming soon....
Make and Model

Specifications
Fluorescence Spectrophotometer


Make and Model

Cary Eclipse with Peltier and Solid Sample Holder
Agilent Technologies

Specifications
  • Source: continuous wave source of Xenon Arc Lamp
  • Detector spectral range 200-900 nm
  • Analysis software enables Spectra scan, 3D-Spectra Scan, quantification, Single read, Time Drive, Kinetics, Anisotropy/Polarization (in both in Spectra Scan and Single Read), Intracellular ion concentration, Quantum yield (Relative and Absolute), Quenching, Lifetime, Absorbance, Wavelength programs, Validation, Pre-Scan, Synchronous scan mode (constant energy and wavelength), 3D Synchronous scan
  • Complete Peltier system with all required accessories enabling Peltier effect temperature control, Temperature range 0⁰ C to ~100⁰ C
  • Suitable Accessories for Liquid & Solid Samples
Fourier Transform Infrared Spectrometer (FTIR)
Make and Model

Thermo Electron Scientific Instruments LLC, Nicolet iS20

Specifications
  • Beam Spiltter: Germanium coated KBr beam splitter
  • Wavelength Range: 11000-350 cm-1
  • Spectral resolution: 0.4 cm-1
  • Laser: Temperature-controlled solid-state Near IR Diode laser
  • Wavelength precision: 0.01 cm-1 
  • Detector: DTGS detector 
  • Performance Verification: Automated Inbuilt NIST-traceable 1.5 MIL polystyrene film
Nuclear Magnetic Resonance (NMR) Spectrometer
Make and Model

ECZS Series 400 MHz NMR SPECTROMETER
JEOL

Specifications
  • Spectrometer Frequency : 400 MHz
  • Solution State Probes :
    • Royal Probe - A Multinuclear Probe with Variable temperature facility to cover nuclei preferably 15N to 31P and Variable temperature accessory for -100oC to +150oC. Automatic tuning and matching for all observation Nuclei.
    • TH5 Probe - Observation Nuclei 15N to 31P and 1H and 19F with Automatic tuning and matching for all observation Nuclei.
  • Spectroscopy by NoD solvent
  • Auto-sampler
  • Delta NMR Data Processing Software
Small Angle X-ray Scattering (SAXS)




Make and Model

XENOCS, Xuess 3.0 HR

Specifications
  • Dual Source Module (Genix 3D Cu, 30 Watts, Cu tube with 50 kV & 06. mA / Genix 3D Mo, 50 Watts , Mo tube with 50 kV & 1 mA
  • Eiger 2 R 1M with 2D hybrid pixel photon counting detector with direct detection of X-rays with a pixel size of 75 um.
  • Ultra High Resolution
  • High Resolution
  • High Flux
  • Very High Flux
  • Ultra High Flux
  • Full open
  • SpecFE based software to control motors slits
  • Capillary Flow Cell
  • Vacuum compatible capillary flow cell
  • Multisample holders for powder and gels
  • Multi sample Peltier temperature stage-20 to 150 degree Celsius
  • Shear Cell system stage
  • Linkam HFSX350 temperature Stage
Time-correlated Single Photon Counting (TCSPC) System

Make and Model

DeltaFlex-01-DD with HPPD detector
Horiba Jobin Yvon IBH Limited

Specifications
  • Modular TCSPC lifetime system with emission monochromator, vertically dispersive optics, DeltaDiode pulsed diode excitation. Picosecond detection module, DeltaHub timing electronics, decay analysis software
UV-VIS-NIR Spectrophotometer
Make and Model

Agilent Technologies, Cary 5000 with DRS 2500

Specifications
  • Double beam, double monochromator, fully automatic
  • Source: Tungsten-halogen and deuterium lamps with built-in mechanism in order to automatically switch the light source during the measurement of the entire UV-VIS-NIR wavelength range
  • Detector: Photomultiplier tube (PMT) detector for the UV-Vis wavelength range and cooled PbS/InGaS detector for the NIR wavelength range
  • Wavelength range: 250-2500 nm
  • DRS option for solid samples is also available
Wide Angle X-ray Scattering (WAXS)




Make and Model

XENOCS, Xuess 3.0 HR

Specifications
  • Dual Source Module (Genix 3D Cu, 30 Watts, Cu tube with 50 kV & 06. mA / Genix 3D Mo, 50 Watts , Mo tube with 50 kV & 1 mA
  • Eiger 2 R 1M with 2D hybrid pixel photon counting detector with direct detection of X-rays with a pixel size of 75 um.
  • Ultra High Resolution
  • High Resolution
  • High Flux
  • Very High Flux
  • Ultra High Flux
  • Full open
  • SpecFE based software to control motors slits
  • Capillary Flow Cell
  • Vacuum compatible capillary flow cell
  • Multisample holders for powder and gels
  • Multi sample Peltier temperature stage-20 to 150 degree Celsius
  • Shear Cell system stage
  • Linkam HFSX350 temperature Stage
X-ray Diffractometer (XRD)
Make and Model

Panalytical, EMPYREAN-QTY1

Specifications
  • X-Ray Generator
    • Operating Voltage: 220-240V, 50 Hz, Single phase
    • Rated voltage: 20-60 KV or better
    • Anode Current 2-60 mA
  • Goniometer
    • Operation mode: Theta-Theta
    • Minimum scan speed: θD/θs coupled 0.02-100o/min
    • θD/θs independent 0.01o/min to 50o/min
  • Min. step size: 0.0001o
X-ray Fluorescence (XRF)

Make and Model

PANalytical, EPSILON 3X FUSION BEAD LENEO

Specifications
  • Concentration range: ppm to percentage
  • Excitation voltage 0-50 kV
  • Excitation current 1mA
X-Ray Photoelectron Spectrometer (XPS) with UPES



Make and Model

Thermo Fisher SCIENTIFIC

Specifications
  • Analyzer
    • 180° double-focusing hemispherical analyzer
    • High-efficiency electron transfer lens
    • 128-channel detector
  • X-ray Source
    • Al Kα micro-focused monochromator
    • Variable spot size (30–400 µm in 5 µm steps)
  • Charge Compensation
    • Dual-beam source
    • Ultra-low energy co-axial electron and Ar+ ion beam Charge Compensation
  • EX06 Ion Gun
    • Energy range 100 eV to 4 keV
  • Sample Handling
    • 4-axis sample stage
    • 60 X 60 mm sample area
    • 20 mm maximum sample thickness
  • Vacuum System
    • Two 250 l/s turbo molecular pumps
    • Auto-firing, 3-filament TSP
  • Software
    • Avantage software including offline data processing sampling capabilities
    • Tilt Module
    • Sample Bias Module